9.59
Model 6036 Legacy
Electrical System
d. Starter Cleaning and Drying
1. While the starter is being removed, wipe away any
grease or dirt that has accumulated around the
starter mounting opening.
2. If reinstalling the starter, clean the exterior of the
starter with an approved solvent. DO NOT submerse
the starter or allow the solvent to contact the starter
bushings.
3. Dry the starter with a clean, lint-free cloth.
e. Starter Periodic Maintenance
A starter requires no routine maintenance beyond the
occasional inspection of the electrical connections, which
must be clean and tight. The starter is not serviceable;
replace a defective starter with a new unit.
f. Starter Installation
1. Position the starter (Fig. 9-31, 1) in its mounting
opening on the flywheel housing. Position the
ground cable (7) over the lower starter mounting
hole. Secure the starter with three 12-point fasteners
(2). Torque nuts to 3.4 lb/ft (4,6 Nm) and torque hex-
head capscrews to 32 lb/ft (43 Nm).
2. Connect the red, positive (+) battery cable (Fig. 9-31,
5) to the upper solenoid stud (4). Install the two red
wires (3) to the upper solenoid stud, and secure with
washer and nut.
3. Connect the blue/orange wire (Fig. 9-31, 6) to the
solenoid mounting stud.
4. Connect the negative (-) battery cable to the battery
terminal.
9.11 CHARGING CIRCUIT
The purpose of the charging circuit is to maintain battery
voltage between 13.8 and 14.2 volts. The key switch
must be in the RUN position with the engine running in
NSorder for the charging system to operate.
The charging circuit consists of the battery and a belt-
driven alternator with an internal voltage regulator. These
components work together to provide electrical power for
the vehicle, including the starting system, operator’s
instrument cluster, horn, solenoids, back-up alarm and all
accessories.
Current flows from the positive post of the battery to the
BATT terminal on the starter motor solenoid.
When the ignition key switch is in the RUN position,
current flows from the instrument cluster to the alternator
D+ terminal, and is used to excite the field windings and
the alternator begins emitting a charge. Current flows
from the alternator B+ terminal to the starter motor B
terminal, then through the positive (+) battery cable to the
battery.
The circuit in the instrument panel connects to the battery
positive terminal through the fuse panel and detects field
voltages in excess of 16 volts or system voltages that are
less than 2-4 volts below battery voltage. Either of these
conditions will cause the warning light on the operator’s
instrument cluster to illuminate.