SECTION 6
BOOM EXTEND CYLINDER
(Early Production)
CURRENT PRODUCTION
VENDOR
STAMPING
EARLY PRODUCTION
IMPORTANT:
There are two similar but distinctly different Boom Extend
Cylinders. Make sure you know which version you have
before ordering replacement parts. On Early Production
cylinders, the gland is installed flush with the cylinder
tube and has “TJB” stamped on the gland. On the
“Current Production” cylinders, the gland has a lip that
bottoms out against the cylinder tube.
PH0342
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
3
4
5
Torque to 150 - 160 lb/ft
(203 - 217 Nm)
Retract
Port
Torque to
150 - 160 lb/ft
(203 - 217 Nm)
Extend
Port
PF0760